CrossCheck Sensor Controller

Profile Made Simple

The CrossCheck Industrial Sensor Controller enhances machine control and product verification. Combined with our innovative CrossCheck Software and wide variety of accessories like the Sensor Universal Mounting Plate & Articulating Arm, Multifunction I/O Device and Visual Signal Indicator — part profile or continuous process inspection has never been easier!

  • Each Controller accepts one or two CrossCheck Sensor(s)
  • Portable keyboard with touch pad makes Shape Tools set up simple
  • Customer provides monitor. Any model acceptable.
  • Short-Range Specifications
  • Long-Range Specifications
  • Controller Dimensions

CrossCheck System Short-Range Specifications (mm):

  CrossCheck Sensor Model
  Specification CC3100-30 CC3100-50 CC3100-75 CC3100-100
Y-Axis Height Range 30 mm 50 mm 75 mm 100 mm
Height Resolution* 0.003 mm 0.005 mm 0.0075 mm 0.010 mm
Height Accuracy* 0.015 mm 0.025 mm 0.0375 mm 0.050 mm
X-Axis Mid Width Range 30 mm 50 mm 75 mm 92 mm
Near/Far Width Range 27/33 mm 42/58 mm 58/91 mm 70/115 mm
Width Resolution* 0.010 mm 0.015 mm 0.025 mm 0.030 mm
Width Accuracy* 0.030 mm 0.050 mm 0.075 mm 0.100 mm
General Max Profile Rate 30 fps
Laser Class 685nm, 3R
Weight Sensor: 0.40 kg (0.88 lbs.); Controller 6 kg (13.22 lbs.)
Controller Power 18VDC to 28VDC (phoenix power plug)
External AC Adapter: 90VAC to 264VAC, 47–63 Hz
Controller to Sensor Interface IEEE 1394b (Firewire)
Host Connectivity Gigabit Ethernet [Text via TCP/IP (Telnet)]
Environment Thermal Stability < .03% / °C
Operating Temperature 5–45 °C
Operating Humidity 5 … 95% (no condensation)
Shock (IEC 68-2-29) 15 g / 6ms
Vibration (IEC 68-2-6) 5 g, 58 … 150 Hz
Enclosure Rating IP-64
*Notes:
  1. Resolution and Accuracy are based on using a Diameter Shape Tool to locate the X,Y center point of a cylinder target whose radius is 10% or more of the sensor width range.
  2. Accuracy is +/- maximum expected deviation from the true value. The reference measurement is the difference between the location of a cylinder in position 1 and position 2. Confidence interval is 95%.
  3. Resolution is 1 standard deviation of 30 sequential measurements on a static target.

CrossCheck System Long-Range Specifications (mm):

  CrossCheck Sensor Model
  Specification CC3250-180 CC3330-325 CC3600-250
Y-Axis Height Range 190 mm 300 mm 300 mm
Height Resolution* 0.019 mm 0.030 mm 0.030 mm
Height Accuracy* 0.095 mm 0.150 mm 0.150 mm
X-Axis Mid Width Range 180 mm 330 mm 250 mm
Near/Far Width Range 145/215 mm 260/340 mm 195/305 mm
Width Resolution* 0.060 mm 0.110 mm 0.083 mm
Width Accuracy* 0.180 mm 0.330 mm 0.250 mm
General Weight – Sensor 1.40 kg (3.08 lbs.) 0.80 kg (1.77 lbs.)
Weight – Controller 6 kg (13.22 lbs.)
Max Profile Rate 30 fps
Laser Class 685nm, 3R
Controller Power 18VDC to 28VDC (phoenix power plug)
External AC Adapter: 90VAC to 264VAC, 47–63 Hz
Controller to Sensor Interface IEEE 1394b (Firewire)
Host Connectivity Gigabit Ethernet [Text via TCP/IP (Telnet)]
Environment Thermal Stability < .03% / °C
Operating Temperature 5–45 °C
Operating Humidity 5 … 95% (no condensation)
Shock (IEC 68-2-29) 15 g / 6ms
Vibration (IEC 68-2-6) 5 g, 58 … 150 Hz
Enclosure Rating IP-64
*Notes:
  1. Resolution and Accuracy are based on using a Diameter Shape Tool to locate the X,Y center point of a cylinder target whose radius is 10% or more of the sensor width range.
  2. Accuracy is +/- maximum expected deviation from the true value. The reference measurement is the difference between the location of a cylinder in position 1 and position 2. Confidence interval is 95%.
  3. Resolution is 1 standard deviation of 30 sequential measurements on a static target.