CrossCheck Laser Profile Systems

Simple, Innovative and Powerful Features

The CrossCheck Laser Profile System consists of three main components:

  • CrossCheck Laser Profile Sensor
  • CrossCheck Industrial Sensor Controller
  • CrossCheck Software

Adobe PDF Download CrossCheck Data Sheet
(Right-click to download. PDF file is 1.3 MB. Need Adobe® Reader? Get it free here.)

  • Short-Range Specifications
  • Short-Range Dimensions
  • Long-Range Specifications
  • Long-Range Dimensions

CrossCheck System Short-Range Specifications (mm):

  CrossCheck Sensor Model
  Specification CC3100-30 CC3100-50 CC3100-75 CC3100-100
Y-Axis Height Range 30 mm 50 mm 75 mm 100 mm
Height Resolution* 0.003 mm 0.005 mm 0.0075 mm 0.010 mm
Height Accuracy* 0.015 mm 0.025 mm 0.0375 mm 0.050 mm
X-Axis Mid Width Range 30 mm 50 mm 75 mm 92 mm
Near/Far Width Range 27/33 mm 42/58 mm 58/91 mm 70/115 mm
Width Resolution* 0.010 mm 0.015 mm 0.025 mm 0.030 mm
Width Accuracy* 0.030 mm 0.050 mm 0.075 mm 0.100 mm
General Max Profile Rate 30 fps
Laser Class 685nm, 3R
Weight Sensor: 0.40 kg (0.88 lbs.); Controller 6 kg (13.22 lbs.)
Controller Power 18VDC to 28VDC (phoenix power plug)
External AC Adapter: 90VAC to 264VAC, 47–63 Hz
Controller to Sensor Interface IEEE 1394b (Firewire)
Host Connectivity Gigabit Ethernet [Text via TCP/IP (Telnet)]
Environment Thermal Stability < .03% / °C
Operating Temperature 5–45 °C
Operating Humidity 5 … 95% (no condensation)
Shock (IEC 68-2-29) 15 g / 6ms
Vibration (IEC 68-2-6) 5 g, 58 … 150 Hz
Enclosure Rating IP-64
*Notes:
  1. Resolution and Accuracy are based on using a Diameter Shape Tool to locate the X,Y center point of a cylinder target whose radius is 10% or more of the sensor width range.
  2. Accuracy is +/- maximum expected deviation from the true value. The reference measurement is the difference between the location of a cylinder in position 1 and position 2. Confidence interval is 95%.
  3. Resolution is 1 standard deviation of 30 sequential measurements on a static target.

CrossCheck System Long-Range Specifications (mm):

  CrossCheck Sensor Model
  Specification CC3250-180 CC3330-325 CC3600-250
Y-Axis Height Range 190 mm 300 mm 300 mm
Height Resolution* 0.019 mm 0.030 mm 0.030 mm
Height Accuracy* 0.095 mm 0.150 mm 0.150 mm
X-Axis Mid Width Range 180 mm 330 mm 250 mm
Near/Far Width Range 145/215 mm 260/340 mm 195/305 mm
Width Resolution* 0.060 mm 0.110 mm 0.083 mm
Width Accuracy* 0.180 mm 0.330 mm 0.250 mm
General Weight – Sensor 1.40 kg (3.08 lbs.) 0.80 kg (1.77 lbs.)
Weight – Controller 6 kg (13.22 lbs.)
Max Profile Rate 30 fps
Laser Class 685nm, 3R
Controller Power 18VDC to 28VDC (phoenix power plug)
External AC Adapter: 90VAC to 264VAC, 47–63 Hz
Controller to Sensor Interface IEEE 1394b (Firewire)
Host Connectivity Gigabit Ethernet [Text via TCP/IP (Telnet)]
Environment Thermal Stability < .03% / °C
Operating Temperature 5–45 °C
Operating Humidity 5 … 95% (no condensation)
Shock (IEC 68-2-29) 15 g / 6ms
Vibration (IEC 68-2-6) 5 g, 58 … 150 Hz
Enclosure Rating IP-64
*Notes:
  1. Resolution and Accuracy are based on using a Diameter Shape Tool to locate the X,Y center point of a cylinder target whose radius is 10% or more of the sensor width range.
  2. Accuracy is +/- maximum expected deviation from the true value. The reference measurement is the difference between the location of a cylinder in position 1 and position 2. Confidence interval is 95%.
  3. Resolution is 1 standard deviation of 30 sequential measurements on a static target.